Modular Data Center

Ict

Modular Data Center

Prefabricated data centres, UPS, precision cooling — Tier I–IV

Overview

What we offer

A complete toolkit — purpose-built for your environment.

A modular data centre is a prefabricated, factory-built data infrastructure solution that delivers the compute, storage, network, power, cooling, and physical security capabilities of a traditional data centre — but in a standardised, rapidly deployable format. Components are engineered and tested at the factory, shipped to site, and integrated in days or weeks rather than months. The result is faster time to operation, more predictable cost, and performance that meets or exceeds custom-built equivalents.

Bangladesh's data centre market is growing at an extraordinary pace. Regulatory changes requiring financial institutions to store customer data locally under Bangladesh Bank's ICT guidelines, combined with the Bangladesh Telecommunication Regulatory Commission's data localisation framework and the requirements of the PDPO 2025 Personal Data Protection Ordinance, are driving significant enterprise investment in local data infrastructure. At the same time, international investors in Bangladesh's Special Economic Zones are demanding data infrastructure that meets international standards — not because of local regulation, but because their global IT governance frameworks require it.

Traditional data centre construction in Bangladesh is slow, expensive, and uncertain. Civil construction delays, imported equipment lead times, MEP contractor coordination, and commissioning punch lists routinely extend project timelines by six to twelve months. A modular approach collapses this timeline dramatically — a pre-engineered modular server room can be operational within eight weeks of order, with all components factory-tested before shipment. For organisations that need data infrastructure urgently — to meet a regulatory deadline, to bring a new application online, or to recover from a disaster — this speed advantage is transformative. We partner with Vericom to deliver modular data centre solutions across Bangladesh, providing end-to-end project management from site assessment to commissioning and beyond.

Brochure summary: SSAL delivers modular data centre solutions including micro data centres and containment systems for indoor and outdoor deployment. Integrating power, cooling, racks, and networking, these scalable solutions enable rapid implementation, flexibility to switch locations, and efficiency — transforming traditional data centre infrastructure for enterprises, telecom operators, and financial institutions.

Rapid Deployment

Modular data centres deploy in eight to sixteen weeks from order to operations — compared to twelve to eighteen months for traditional construction. For organisations facing regulatory deadlines or business continuity requirements, this speed advantage is often decisive.

TIA-942 Tier I–IV Compliance

Every modular data centre we design is benchmarked against TIA-942 Tier methodology. We document the compliance basis for each tier claim — essential for colocation operators, financial institutions, and government clients whose customers require evidence of infrastructure resilience.

Precision Cooling (CRAC/CRAH)

Computer Room Air Conditioning (CRAC) and Computer Room Air Handling (CRAH) units maintain temperature within ±1°C and humidity within ±5% RH — essential for semiconductor reliability and preventing condensation on server components. Hot aisle/cold aisle containment eliminates air mixing and improves cooling efficiency by up to 40%.

Online Double-Conversion UPS

Online double-conversion UPS systems provide zero transfer time on utility power failure — the IT load never sees a power interruption. Lithium-ion battery options reduce footprint by 50% versus VRLA lead-acid batteries while delivering longer service life and real-time battery health monitoring.

Intelligent Power Distribution (PDU)

Rack-mounted intelligent PDUs with per-outlet metering, remote switching, and threshold alerting provide granular power visibility at the server level — enabling accurate capacity planning and early detection of power anomalies before they become outages.

Process

How it works

One accountable team from first site visit to handover — certified engineers, manufacturer-trained installers, and documented compliance at every stage.

  1. Requirements Definition

    We work with your IT, facilities, and finance teams to define your data centre requirements: IT load capacity (kW), rack count, power redundancy level (N, N+1, 2N), cooling approach, physical security requirements, and target TIA-942 Tier level. We also assess your site constraints — floor load capacity, available floor area, ceiling height, building services connections (power, cooling water, drainage), and access for delivery of modular components.

  2. System Design & Tier Compliance

    We produce a modular data centre design that achieves your target TIA-942 Tier level. Tier I provides basic capacity with planned maintenance requiring downtime. Tier II adds redundant components. Tier III is concurrently maintainable — any component can be taken offline for maintenance without interrupting IT operations. Tier IV is fault tolerant, with two completely independent delivery paths for all infrastructure. Design documentation includes power distribution single-line diagrams, cooling system schematics, network cabling layouts, and physical security integration drawings.

  3. Factory Build & Testing

    Vericom's modular data centre components are engineered and assembled in a controlled factory environment. Precision cooling units, UPS systems, PDUs, and rack systems are factory-configured and tested before shipment. This factory acceptance testing (FAT) eliminates the most common sources of commissioning delay — wiring errors, firmware incompatibilities, and configuration mistakes that typically surface only when equipment is installed on site.

  4. Site Preparation & Civil Works

    We coordinate and supervise the civil preparation works at your site: concrete slab assessment and reinforcement (if needed for floor load), power supply termination (HV/LV switchgear, generator connection), chilled water supply (for chilled water cooling systems), access road and delivery crane planning, and raised floor installation. BNBC 2020 structural and electrical requirements govern all civil works.

  5. Installation & Integration

    Modular components are delivered to site and positioned using crane or forklift. Our engineers connect power, cooling, network, and management interfaces between modules. Physical security systems — biometric access control, CCTV, and FM-200 or VESDA fire suppression — are integrated with the building management system and security operations platform. Structured cabling is installed to TIA-942 within the data centre white space.

  6. Commissioning & Handover

    We conduct integrated commissioning testing: IT load testing, cooling system performance verification (PUE measurement), UPS switchover testing, generator load transfer testing, fire suppression abort and discharge testing, and access control and CCTV verification. You receive a commissioning report, as-built drawings, equipment warranties, and a facilities management handover package covering preventive maintenance schedules for all systems.

Step-by-step process illustration for modular data center

Applications

Built for every industry

Where this solution is deployed — and the compliance environment each sector brings with it.

Deployment site for modular data center

Banking & Financial Services

Bangladesh Bank ICT Guideline v4.0 requires banks to maintain data centres with documented resilience characteristics. We design and deliver bank data centres that satisfy Bangladesh Bank's requirements for physical security, redundant power, air conditioning, and fire suppression — with the compliance documentation your internal IT audit team and Bangladesh Bank examiners require.

Telecommunications & ISPs

Internet service providers and telecommunications companies require carrier-grade infrastructure — high-density power, precision cooling for active network equipment, and redundant power delivery. We deliver modular data centres sized for telecom equipment heat densities and BTTC licensing requirements.

Deployment site for modular data center

Government & Public Sector

Government ministries and state enterprises are investing in sovereign data infrastructure aligned with Bangladesh's Digital Bangladesh agenda and e-governance expansion. We design government data centres with Tier III concurrently maintainable infrastructure and the physical security posture required for classified and sensitive data environments.

Healthcare & Hospital Groups

Hospital groups deploying electronic medical records (EMR), PACS radiology imaging, and digital pharmacy systems require local data infrastructure that provides always-on availability for clinical applications. We deliver hospital server room fit-outs and small modular data centres with appropriate resilience and clinical-grade physical security.

Deployment site for modular data center

Export Processing Zones & Industrial Parks

International companies operating in Bangladesh's BEPZA or KEPZ zones require data infrastructure meeting their global IT governance standards. Modular data centres deliver international-standard infrastructure without the delays of local construction — meeting the timelines demanded by global headquarters IT departments.

Educational Institutions

Universities expanding their digital learning platforms, student information systems, and research computing capabilities require server room infrastructure that can grow with institutional ambitions. We design right-sized modular server rooms with expandable capacity and management tools sized for university IT teams.

Products & Brands

Powered by the brands you trust

We are authorised partners for every line we propose — back-to-back manufacturer warranties and channel-certified installers on every project.

Brand

What It Provides

Vericom

Comprehensive data centre infrastructure brand providing modular data centre systems, structured cabling, rack systems, power distribution units, and cable management solutions engineered for TIA-942 compliant data centre environments.

Supporting Technology Partners:

  • Precision cooling (CRAC/CRAH): Leading global precision cooling brands
  • UPS Systems: Online double-conversion UPS with lithium-ion battery option
  • Raised flooring: Anti-static, high-load access floor systems
  • Fire suppression: Xtralis VESDA + FM-200/Novec 1230 (see Fire Safety System)
  • Physical security: ZKTeco/Honeywell access control + Hikvision CCTV (see Access Control and Surveillance solutions)

Resources

Download

One-pagers and supporting collateral you can share with your team or compliance committee.

Related Industries

Next step

Ready to scope this solution?

Book a free site survey or request a quotation — both are no-obligation. One accountable team from survey to handover, backed by a 24/7 support hotline.